Home > LVDT Products & Specs > Free-Core LVDTs > Free-Core AC-LVDTs > PRH 812 General Purpose LVDT Position Sensors - METRIC

PRH 812-006 Series General Purpose AC-LVDT Position Sensors - METRIC

A METRIC PRODUCT ... Looking for Standard? Click Here!
Contact Us for More Information

PRH 812 General Purpose LVDT Position Sensors
click the image for an enlarged view

Description

Macro Sensors' PRH 812 Series of AC-LVDTs are 20.6 mm diameter general-purpose LVDT linear position sensors that feature larger core-to-bore clearance than the standard PR 750 Series of AC-LVDTs. They were designed primarily for use in legacy OEM applications, and are cost-effective exact replacement LVDTs that offer the same form, fit, and function as competitors' products of the same size and range.

Available in full scale measuring ranges of ±1 mm to ±250 mm, PRH 812 LVDTs offer 1.6 mm radial core-to-bore clearance with the standard 6.35 mm diameter core supplied. They feature high resolution, excellent repeatability, and low hysteresis, as well as the highest sensitivity consistent with good linearity. The maximum linearity error of any of these sensors is ±0.25% of full range output (FRO), using a statistically best-fit straight line derived by the least squares method.

The proven reliability of PRH 812 Series LVDTs is a direct result of manufacturing processes and assembly techniques developed and optimized by Macro Sensors personnel over many years of making LVDTs. Their environmental robustness stems from the materials of their construction, such as glass-filled polymer coil forms for thermal stability and stainless steel housings that act as magnetic shields to reduce the effects of any external AC magnetic fields. Their sealing meets IEC standard IP-61.

Macro Sensors offers several options that permit a user or OEM to customize PRH 812 LVDTs or to match them to an existing application, including Teflon™ bore liners, metric threaded cores, smaller diameter cores for greater core-to-bore clearance and/or lower core mass, and construction for resistance to mild nuclear radiation. For OEMs, Macro Sensors can design and produce custom or private-labeled PRH 812 LVDTs, including units with different lead wire colors, exit points, configurations, or connectors, vented units for operation in pressurized fluids, and units for higher temperature operation. Contact the Applications Engineering group at Macro Sensors for help with any OEM or special LVDT requirements.

All PRH 812 Series LVDTs will operate properly with any conventional differential input LVDT signal conditioners, but some PRH 812 LVDTs could exhibit reduced performance if utilized with ratiometric input signal conditioners. Macro Sensors offers a full line of signal conditioners that can deliver optimum performance from any PRH 812 Series LVDT.

Features

20.6 mm diameter legacy replacements

Ranges of ±1 mm to ±250 mm

1.6 mm radial core-to-bore clearance

Non-linearity less than ±0.25% of FRO

150°C operating temperature

Coil assembly sealed to IEC IP-61

Magnetically shielded SS housing

Applications

Machine Tools

Materials Testing

Industrial Robots

Checkweigher Scales

Packaging Machinery

Valve Position Sensing

Hydraulic Cylinder Position

Automated Assembly Equipment

GENERAL SPECIFICATIONS

A METRIC PRODUCT ... Looking for Standard? Click Here!

Input Voltage
3.0 Vrms (nominal)
Input Frequency
2.5 - 3.3 kHz
Linearity Error
</=±0.25% of FRO
Repeatability Error
<±0.01% of FSO
Hysteresis Error
<±0.01% of FSO
Operating Temperature
-55°C to +150°C
Thermal Coefficient of Sensitivity
-0.02%/°C (nominal)
Vibration Tolerance
20 g to 2 kHz
Shock Survival
1000 g, 11 ms
Contact Us for More Information

UNIT SPECIFICATIONS

A METRIC PRODUCT ... Looking for Standard? Click Here!

PARAMETER
UNIT OF MEASURE
PRH 812
-050-006
PRH 812
-100-006
PRH 812
-200-006
PRH 812
-500-006
PRH 812
-1000-006
PRH 812
-2000-006
PRH 812
-3000-006
PRH 812
-4000-006
PRH 812
-5000-006
PRH
812
-10000-006
Nominal Range
Millimeter
±1
±2.5
±5
±12.5
±25
±50
 ±75
±100
±125
 ±250
Sensitivity
mV/V/
Millimeter
230
165
95
26
15.3
8.6
9.1
7.1
5.9
2.8
Primary Impedance
Ohms
400
1070
1900
460
430
670
115
275
600
550
Dimension "A"
Millimeter
28.7
46.0
63.5
139.7
168.1
254.0
325.4
397.3
454.1
783.3
Dimension "B"
Millimeter
20.3
33.0
41.9
87.6
101.6
134.6
142.2
177.8
177.8
215.9
Dimension "N"
Millimeter
14.3
23.0
31.7
69.9
84.1
127.0
162.6
198.6
227.1
391.4
Weight, Body
Grams
37
57
74
114
131
238
312
392
474
814
Weight, Core
Grams
4.0
6.2
8.5
19.0
21.3
28.3
30.0
42.8
42.8
55.4
Contact Us for More Information

Mechanical Drawing & Wiring Diagrams

A METRIC PRODUCT ... Looking for Standard? Click Here!

PRH 812-006 Metric General Purpose LVDT Position Sensors - Mechanical Drawing & Wiring Diagram

Contact Us for More Information

Support Electronics

The following Signal Conditioners are compatible with the PRH 812-006 LVDT:

Model
Power Input
Output
10-30 V DC (24 V DC nominal, 100 mA max.) (10 V DC nominal, 160 mA max.)
0 to ±10 V DC, 5 mA max.
0 to 10 V DC, 5 mA max.
4 to 20 mA sourcing into 550 Ohms (max.) loop resistance

The following Digital Panel Meters are compatible with the PRH 812-006 LVDT:

Model
Power Input
Output
115 VAC to 220 V AC or 24 V DC optional
LED Readout, dual channel, 0 to 10 VDC output, Optional RS-232 or Ethernet
115 V AC to 220 V AC or 24 V DC optional
LED Readout, single channel, 0 to 10 VDC output, Optional RS-232
Contact Us for More Information

Options

Teflon Bore Liner
Reduced-Diameter Core
Metric-Threaded Core
Radiation-Resistant Construction

NOTE: some options not available on certain models

Contact Us for More Information

Ordering Information

A METRIC PRODUCT ... Looking for Standard? Click Here!

• For Teflon® bore liner option, add -010 after model number with range (not available with -080 option)
• For small diameter core option, add -020 after model number with range
• For mild radiation resistant option, add -080 to model number with range (not available with -010 option)
• For multiple options, add sum of dash numbers after model number with range
• For accessories, please visit the accessories page.