AST Macro Sensors - A Division of Howard A. Schaevitz Technologies Inc. - LVDT  Based Position Sensors and Support Electronics - Pennsauken, NJ, Phone: 856-662-8000, email: lvdts@macrosensors.com
Product Highlights - click here for new and featured products
LVDT Products & Specs
Manuals & User Info
LVDT Applications
Product News
About Macro Sensors
点击这里我们的中国网址
Home > LVDT Products & Specs > Harsh Environment > Harsh-Environment AC > SQ 1250 Heavy Duty LVDT Position Sensors

SQ 1250 Series Heavy Duty LVDT Position Sensors

Contact Us for More Information

SQ 1250 Heavy Duty LVDT Position Sensors
click the image for an enlarged view

Description

The Macro Sensors SQ 1250 Series of heavy duty LVDTs were developed specifically to measure position or motion in mill-type hostile environments. These rugged and reliable contactless sensors, available in measuring ranges from ±0.50 inches to ±10.00 inches, have their electrical assembly totally encapsulated within a heavy duty aluminum housing, with their electrical connections made to screw-terminal style barrier strips. This complete encapsulation of SQ 1250 Series LVDTs allows them to withstand the high shock and vibration levels typically encountered in mill environments and permits them to meet the IEC IP-64 sealing standard against the intrusion of splashed water and other liquids.

SQ 1250 Series LVDTs are electrically and magnetically double shielded to maximize noise immunity and minimize their susceptibility to external AC magnetic fields developed by electric motors, transformers, etc. Because core shaft misalignment occurs often in mill applications, all SQ 1250 Series sensors incorporate Teflon™ bore liners to reduce friction and wear between the LVDT's core and its bore under such conditions, especially when measuring oscillatory motions.

SQ 1250 Series position sensors offer the high resolution, excellent repeatability, and low hysteresis associated with LVDT technology, as well as the highest sensitivity consistent with good linearity. The maximum linearity error for an SQ 1250 LVDT is ±0.25% of full range output, using a statistically best-fit straight line derived by the least squares method.

SQ 1250 Series LVDTs feature constant sum-of-the-secondaries output, so they can be used equally well with conventional differential input LVDT signal conditioners, such as those illustrated in Macro Sensors' series 9000 technical bulletins, or with ratiometric LVDT signal conditioners found in some industrial control systems.

Typical applications of SQ 1250 Series LVDTs are measuring roller gap position for hydraulic servo systems used to control primary metals rolling mills, sizing lumber to maximize yield in sawmills, maintaining proper calender roll position in paper mills, controlling steam valve opening in electric power plants, and measuring raker boom height in wastewater treatment plants.

Features

Rugged, heavy duty construction

Ranges of ±0.50 inches to ±10.00 inches

Non-linearity less than ±0.25% of FRO

300°F (150°C) operating temperature

Assembly sealed to IEC IP-64

Applications

Steel and aluminum mills

Electric Power Plants

Forges and Foundries

Pulp and Paper Mills

Lumber and Saw Mills

Wastewater Treatment Plants

GENERAL SPECIFICATIONS

Input Voltage
3.0 Vrms (nominal)
Input Frequency
2.5 to 3.0 kHz
Linearity Error
<±0.25% of FRO
Repeatability Error
<0.01% of FSO
Hysteresis Error
<0.01% of FSO
Operating Temperature
-65°F to +300°F
Operating Temperature
-55°C to +150°C
Thermal Coefficient of Sensitivity
-0.01%/°F (nominal)
Thermal Coefficient of Sensitivity
-0.02%/°C (nominal)
Vibration Tolerance
20 g to 2 kHz
Shock Survival
1000 g, 11 ms
Contact Us for More Information

UNIT SPECIFICATIONS

PARAMETER
UNIT OF MEASURE
SQ 1250
-500
SQ 1250
-1000
SQ 1250
-2000
SQ 1250
-3000
SQ 1250
-4000
SQ 1250
-5000
SQ 1250
-6000
SQ 1250
-7500
SQ 1250
-10000
Nominal Range
Inches
±0.05
±1.0
±2.0
 ±3.0
±4.0
±5.0
±6.0
±7.5
 ±10.0
Nominal Range
Millimeter
±12.5
±25
±50
 ±75
±100
±125
±150
±190
 ±250
Sensitivity
mV/V/
.001 Inch
0.73
0.39
0.24
0.27
0.18
0.14
0.12
0.12
0.08
Sensitivity
mV/V/
Millimeter
28.7
15.4
9.4
10.6
7.1
5.5
4.7
4.7
3.1
Primary Impedance
Ohms
1420
1350
990
215
430
1170
730
1380
1070
Dimension "A"
Inches
5.74
6.88
10.25
13.09
15.92
18.16
18.16
23.37
31.14
Dimension "A"
Millimeter
145.8
174.8
260.4
332.5
404.4
461.3
461.3
593.6
790.0
Dimension "B"
Inches
3.45
4.00
5.30
5.60
6.20
7.00
6.20
7.00
9.50
Dimension "B"
Millimeter
87.6
101.6
134.6
142.2
157.5
177.8
157.5
177.8
241.3
Dimension "N"
Inches
2.59
3.32
5.07
6.45
7.65
8.94
8.94
11.55
15.38
Dimension "N"
Millimeter
65.8
84.3
128.8
163.8
194.3
227.1
227.1
293.4
390.7
Weight, Body
Ounces
11.8
14.4
20.0
26.6
31.4
34.6
34.6
42.4
53.9
Weight, Body
Grams
335
408
567
741
890
981
981
1202
1528
Weight, Core
Ounces
0.72
0.83
1.20
1.23
1.30
1.40
1.30
1.40
2.20
Weight, Core
Grams
20.4
23.5
34.0
34.9
36.9
39.7
36.9
39.7
62.4
Contact Us for More Information

Mechanical Drawing & Wiring Diagrams

SQ 1250 Heavy Duty LVDT Position Sensors - Mechanical Drawing & Wiring Diagram

Contact Us for More Information

Support Electronics

The following Signal Conditioners are compatible with the SQ 1250 LVDT:

Model
Power Input
Output
10-30 V DC (24 V DC nominal, 100 mA max.) (10 V DC nominal, 160 mA max.)
0 to ±10 V DC, 5 mA max.
0 to 10 V DC, 5 mA max.
4 to 20 mA sourcing into 550 Ohms (max.) loop resistance

The following Digital Panel Meters are compatible with the SQ 1250 LVDT:

Model
Power Input
Output
115 VAC to 220 V AC or 24 V DC optional
LED Readout, single channel, 0 to 10 VDC output, Optional RS-232 or Ethernet
115 V AC to 220 V AC or 24 V DC optional
LED Readout, dual channel, 0 to 10 VDC output, Optional RS-232
Contact Us for More Information

Ordering Information

• For standard SQ 1250, order by model number with range
• For metric threaded core option, add -006 after model number with range
• For accessories, please visit the accessories page.

Contact Us for More Information