GHSAR 750-A Series Air-Extend/Spring-Retract AC-LVDT Position Sensors

Contact Us for More Information

GHSAR 750-A Series Spring-Loaded Single-Ended DC-LVDT Position Sensors
click the image for an enlarged view

Description

The Macro Sensors GHSAR 750-A Series of 3/4 inch diameter air-extend/spring-retract AC-LVDTs are designed for a wide range of cycled position measurement and automated dimensional gaging applications where it is necessary or desirable to move the probe out of the way between readings. These rugged hermetically sealed sensors are constructed entirely of stainless steel and intended for general industrial use. The coil windings are sealed against hostile environments to IEC standard IP-68. Electrical termination is through a radially mounted sealed connector, which results in a much reduced installed length. The mating connector plug is supplied with the unit.

The sensor consists of an air-extend/spring-retract shaft running in a precision sleeve bearing and connected to the core of an LVDT. The shaft is extended by introduction of a low-pressure (10-30 psi), clean, dry air supply, with a regulated flow, through a barbed fitting on the end of the unit for 1/4 inch I.D. hose. With the release of pressure, an internal spring returns the probe to its retracted position. The use of a precision sleeve bearing results in measurement repeatability of 0.0001 inches (2.5 ìm) or better. The contact tip supplied is an AGD standard number 9 made from black oxide hardened tool steel. It is fully interchangeable with other 4-48-threaded AGD contact tips. The combination of air actuation and a through-bore design allows for repeated purging of the sensor's bearings to remove potential contaminants. The output from the LVDT can be connected to any standard LVDT signal conditioner and then passed to a gaging column display, digital readout, or computer based data acquisition system. Operation with ratiometric LVDT signal conditioning is not recommended. Macro Sensors offers a full line of LVDT signal conditioners that will deliver optimum performance from any GHSAR 750-A Series LVDT. For additional information on signal conditioners, please visit our website at www.macrosensors.com.

Available in ranges of ±0.050 inch (±1.25 mm) to ±2.00 inches (±50 mm), the maximum linearity error for a GHSAR 750-A Series sensor is ±0.25% of full range output using a statistically best-fit straight line derived by the least squares method.

For simplified mounting the GHSAR 750-A has a 1/2-20 UNF-2A thread on the front of the housing, permitting the user to install the LVDT in a mating threaded part or by using the two hex nuts furnished with the sensor. This results in a ready-to-use package for position measurements and longer range gaging applications.

For additional information and important installation considerations, we strongly urge you to visit www.macrosensors.com/lvdt_macro_sensors/
lvdt_products/air_extend/

Features

Low pressure air-extend / spring-retract plunger

Ranges of ±0.050 inch to ±2.00 inches

Non-linearity less than ±0.25% of FRO

Repeatability of 0.0001 inch

Radial connector with mating plug included

Coil environmentally sealed to IEC IP-68

Applications

Cycled measurement functions

Industrial gaging systems

Fabricated metal products gaging

Large shaft TIR measurements

GENERAL SPECIFICATIONS

Input Voltage
3.0 Vrms (nominal)
Input Frequency
2.5 to 3.0 kHz
Linearity Error
<±0.25% of FRO
Repeatability Error
<0.0001 inch (2.5 µm)
Operating Temperature
-65°F to +220°F
Operating Temperature
-55°C to +105°C
Thermal Coefficient of Sensitivity
-0.01%/°F (nominal)
Thermal Coefficient of Sensitivity
-0.02%/°C nominal
Air Supply
10-30 psi, clean, dry Flow regulatable
Contact Us for More Information

UNIT SPECIFICATIONS

PARAMETER
UNIT OF MEASURE
GHSAR 750-050-A
GHSAR 750-125-A
GHSAR 750-250-A
GHSAR 750-500-A
GHSAR 750-1000-A
GHSAR 750-2000-A
Nominal Range
Inches
±0.050
±0.125
±0.025
±0.050
±1.00
±2.00
Nominal Range
Millimeter
±1.25
±3.0
±6.3
±12.5
±25.0
±50.0
Sensitivity
mV/V/.001 in
6.1
3.9
2.5
0.65
0.61
0.37
Sensitivity
mV/V/mm
240
153
98
26
24
14
Primary Impedance
Ohms
325
735
1400
1200
1250
2150
Pretravel
Inches
0.12
0.13
0.10
0.10
0.05
0.02
Pretravel
Millimeter
3.0
3.3
2.5
2.5
1.3
0.5
Overtravel
Inches
0.12
0.13
0.10
0.10
0.05
0.02
Overtravel
Millimeter
3.0
3.3
2.5
2.5
1.3
0.5
Dimension "A" (retracted)
Inches
4.27
4.75
5.32
9.34
10.71
16.87
Dimension "A" (retracted)
Millimeter
108
121
135
237
272
428
Dimension "A" (extended)
Inches
4.61
5.26
6.02
10.54
12.81
20.91
Dimension "A" (extended)
Millimeter
117
134
153
268
322
531
Dimension "B"
Inches
3.51
4.15
4.91
9.05
10.51
16.35
Dimension "B"
Millimeter
89
105
125
230
267
415
Dimension "C"
Inches
1.97
2.60
3.35
5.88
7.34
10.87
Dimension "C"
Millimeter
50
66
85
149
186
276
Weight
Ounces
2.9
3.4
4.0
6.0
6.3
10.2
Weight
Grams
82
96
113
170
179
290
Contact Us for More Information

Mechanical Drawing & Wiring Diagrams

GHSAR 750-A Series Spring-Loaded Single-Ended DC-LVDT Position Sensors - Mechanical Drawing and Wiring Diagram

Contact Us for More Information

Ordering Information

• Order by model number with range
• Find compatible accessories and signal conditioners

Contact Us for More Information