Low Cost Spring Loaded
LVDT Position Sensors
| Input Voltage | 3.0 Vrms (nominal) |
| Input Frequency | 2.5 to 3.0 kHz |
| Linearity Error | < ±0.5% of FRO |
| Operating Temperature | -20 °F to +220 °F |
| -30 °C to +105 °C | |
| Thermal Coefficient of Sensitivity | -0.015%/°F (nominal) |
| -0.03%/°C (nominal) | |
| Vibration Tolerance | 20 g to 2 kHz |
| Shock Survival | 100 g, 11 ms |
- Medium accuracy dimension gaging
- Cost sensitive gaging arrays
- Short range motion control
- X-Y stage position measurement
- Standard 3/4" [19 mm] diameter
- Ranges of ±0.100" to ±0.300" [±2.5 mm to
±7.5 mm] - Non-linearity less than ±0.5% of FRO
- 220°F (105°C) operating temperature
- AGD number 9 hardened contact tip
The GSA 750 series of short range spring loaded position sensors were developed for cost sensitive applications requiring LVDT reliability and performance. Available in ranges of ±0.10 inches to ±0.30 inches, these sensors offer the excellent measurement capabilities of an LVDT at very economical prices. This makes GSA 750 series LVDTs especially attractive for student projects, low overhead machine and fabrication shops, and R & D laboratories on a limited budget.
GSA 750 series sensors have a stainless steel housing and probe shaft, but utilize nylon sleeve bearings and an external helical spring to reduce costs. The LVDT's probe shaft accepts interchangeable AGD contact tips and is supplied with a number 9 hardened tip. The LVDT's body is encapsulated with epoxy to meet IEC IP-62 sealing requirements and magnetically shielded to reduce effects from external AC fields.
GSA 750 sensors are compatible with any of the Macro Sensors LVDT support electronics featured in series 9000 technical bulletins. They are often utilized with our low cost signal conditioner to make a cost effective short range position measuring system.
| Parameter | Unit of Measure | GSA 750-100 | GSA 750-200 | GSA 750-300 |
| Nominal Range | inches | ± 0.100 | ± 0.200 | ± 0.300 |
| mm | ± 2.5 | ± 5.0 | ± 7.5 | |
| Sensitivity | mV/V/.001 in | 3.8 | 2.1 | 2.1 |
| mV/V/mm | 152 | 83 | 83 | |
| Primary Impedance | ohms | 760 | 1110 | 1110 |
| Dimension "A" | inches | 1.75 | 2.50 | 2.50 |
| mm | 44.5 | 63.5 | 63.5 | |
| Dimension "B" | inches | 0.79 | 0.83 | 1.64 |
| mm | 20.1 | 21.1 | 41.6 | |
| Dimension "C" | inches | 0.43 | 0.56 | 1.28 |
| mm | 10.9 | 14.1 | 32.5 | |
| Pretravel | inches | 0.21 | 0.40 | 0.63 |
| mm | 6.0 | 11.3 | 18.0 | |
| Overtravel | inches | 0.015 | 0.033 | 0.056 |
| mm | 0.42 | 0.94 | 1.60 | |
| Weight - Core | ounces | 1.9 | 2.3 | 2.4 |
| grams | 52 | 64 | 68 |

For standard GSA 750, order by model number with range.
For accessories, please visit the Accessories Page.
Macro Sensors also offers a full line of LVDT signal conditioners, controllers and indicators that deliver optimum performance from any AC operated LVDT. For additional information, please visit the Electronics/Signal Conditioning Page.