  • Available for use with AC or DC LVDTs
  • Available for 120-220V AC or 24 V DC operation
  • Four independently programmable set points
  • Available with four 5.0 A Form A relays
  • Available with 0-10 V DC or 4-20 mA outputs
  • Available with RS-232 or Ethernet ports

The DMC Series Dual-Channel Controllers and the DMI Series Single-Channel Indicators can be used in conjunction with AC LVDTs and DC LVDTs to make up a comprehensive, reliable, measurement system. The combination can be applied to a wide variety of demanding measurement applications, such as in process gaging in automated assembly machinery, differential measurements in thickness gaging, and other comparative measurements. Utilize the units' programmable set points, relays and PLC capabilities (DMC units only) and you have an economical solution when you need control functions for comparative and direct measurements in smaller automated systems. The 6-digit (DMC) and 5-digit (DMI) alphanumeric LED displays provide easy to follow setup prompts for all LVDT parameters using the intuitive scrolling text configuration menus.

The LVDT input module of the DMC-A2 Series Dual-Channel AC LVDT Controller is designed to drive and condition the signals from two AC LVDT transducers, while the input module of the DMI-A1 Series Single-Channel AC LVDT Indicator is designed to drive and condition the signal from a single AC LVDT. The input module of the DMI-D1 Series Single-Channel DC-LVDT Indicator is designed to drive and condition the signal from a single DC LVDT.* The modules contain two high-speed micro controllers and a 16-bit dual channel A/D converter which communicate internally via the .2C data bus. When the DMC-A2 and DMI-A1 are used with AC LVDTs, one of the micro controllers generates the sine wave for the AC LVDT excitation frequency. These frequencies are produced as multiples of the line frequency (either 50 Hz or 60 Hz that is selectable via the scrolling text menus). Up to 16 excitation frequencies are available and are selected using the scrolling text menus.

The 16-bit A/D converter has over 130 dB noise rejection at the excitation frequencies and is capable of 40 Hz averaged output on 45 samples. Scrolling text menus provide quick access to a range of configuration modes for easy AC LVDT application setup.

Units operate on 120-220 V AC input power (although the DMI-A1 is available for 24 V DC operation) and can be purchased with either 0-10 V DC or 4-20 mA analog outputs. Other options include four 5A Form A relays, and ports for either RS-232 serial, or Ethernet communication. A free software configuration utility for all models is also available for download.

* Consult factory for DMC-D2 Series Dual-Channel DC LVDT Controller for DC LVDTs

  • DMC-A2 Series
  • DMI-A1 Series
  • DMI-D1 Series
DMC-A2 Series Specifications - (click tabs above for DMI-A1 and DMI-D1 Series Specifications)
General
Digital Display 14-segment alphanumeric, 0.56” (14.2 mm) LEDs
Display Color Red
Display Range -199999 to 999999
Display Update Rate 1, 4, 10 or 20 times per second
Display Dimming 8 brightness levels. Front panel selectable
Scrolling Display Text Messaging Full alphanumeric text characters supported
Polarity Assumed positive. Displays – negative
Annunciators 6 red LEDs on front panel; one per setpoint
Front Panel Controls PROGRAM, UP, and DOWN buttons
Power Supplies Standard high voltage AC power supply 85-265 VAC, or optional low voltage DC power supply 10-72 V DC
Environmental
Operating Temperature 32 °F to 122 °F
0 °C to 50 °C
Storage Temperature -4 °F to 158 °F
-20 °C to 70 °C
Relative Humidity 95% (non-condensing) at 104°F (40°C)
Mechanical
Case Dimensions 1/8 DIN, 3.78” x 1.89”
96 x 48 mm
Case Depth 5.39" (137 mm) maximum
Case Material 94V-0 UL rated self-extinguishing polycarbonate
Weight 0.79 lbs., 0.96 lbs. when packed
11.5 oz., 14 oz. when packed
Approvals
CE As per EN-61000-3/4/6 and EN-61010-1
LVDT Input Module
Excitation Voltage 3 V rms sine wave, zero DC component THD <2% (1.2 kHz)
Excitation Frequency x 16 selectable frequencies
available (1.2 kHz to 11.5 kHz).
Crystal locked, software driven
Temperature Coefficient ± 50 ppm/ °C of full scale (typ.)
Dual LVDT Inputs 30 kΩ input impedance. Synchronous demodulation of excitation carrier. >130 dB rejection of excitation carrier
Frequency Response 500 Hz (–3 dB) low-pass filter
Analog to Digital Dual channel ΣΔ A/D converter approaching 19-bit resolution. Ratiometric operation relative to excitation voltage magnitude
Dual Output Rates Rapid and average response outputs. 1 Hz, 2 Hz, 10 Hz, 20 Hz, 40 Hz averaged
Line Frequency Rejection 50 or 60 Hz noise rejection
Relay Output Modules
Four Relay Module Available with four 5 A Form A Relays;
5 A 240 V AC, 4 A 24 VDC
Isolation 3000 V. UL and CSA listed
DMC-A2 Series Ordering Information

For DMC-A2 Dual-Channel Controller for AC LVDTs, with 120-220 V AC input power, four (4) independently programmable set points, four (4) 5 A Form A relays, 0-10 V DC analog output, and RS-232 serial port, order by Model Number:

DMC-A2-821

For DMC-A2 Dual-Channel Controller for AC LVDTs, with 120-220 V AC input power, four (4) independently programmable set points, four (4) 5 A Form A relays, 0-10 V DC analog output, and Ethernet port, order by Model Number:

DMC-A2-822

Downloads
DMI-A1 Series Specifications - (click tabs above for DMC-A2 and DMI-D1 Series Specifications)
General
Digital Display 7-segment, 0.56” (14.2 mm) LEDs
Display Color Red
Display Range -19999 to 99999
Display Update Rate 10 times per second
Display Dimming 8 brightness levels. Front panel selectable
Polarity Assumed positive. Displays – negative
Annunciators 6 red LEDs on front panel
Front Panel Controls PROGRAM, UP, and DOWN buttons
Power Supplies Standard high voltage AC power supply 85-265 VAC, or optional low voltage DC power supply 10-72 V DC
Environmental
Operating Temperature 32 °F to 122 °F
0 °C to 50 °C
Storage Temperature -4 °F to 158 °F
-20 °C to 70 °C
Relative Humidity 95% (non-condensing) at 104°F (40°C)
Mechanical
Case Dimensions 1/8 DIN, 3.78” x 1.89”
96 x 48 mm
Case Depth 5.39" (137 mm) maximum
Case Material 94V-0 UL rated self-extinguishing polycarbonate
Weight 0.79 lbs., 0.96 lbs. when packed
11.5 oz., 14 oz. when packed
Approvals
CE As per EN-61000-3/4/6 and EN-61010-1
LVDT Input Module
Excitation Voltage 3 V rms sine wave, zero DC component THD <2% (1.2 kHz)
Excitation Frequency x 16 selectable frequencies
available (1.2 kHz to 11.5 kHz).
Crystal locked, software driven
Temperature Coefficient ± 50 ppm/ °C of full scale (typ.)
LVDT Input 30 kΩ input impedance. Synchronous demodulation of excitation carrier. >130 dB rejection of excitation carrier
Frequency Response 500 Hz (–3 dB) low-pass filter
Analog to Digital Single channel ΣΔ A/D converter approaching 19-bit resolution. Ratiometric operation relative to excitation voltage magnitude
Output Rate 10 Hz average response output
Line Frequency Rejection 50 or 60 Hz noise rejection
Relay Output Modules
Four Relay Module Available with four 5 A Form A Relays;
5 A 240 V AC, 4 A 24 VDC
Isolation 3000 V. UL and CSA listed
DMI-A1 Series Ordering Information

For DMI-A1 Single-Channel Indicator for AC LVDTs, with 120-220 V AC input power, four (4) independently programmable set points, and 0-10 V DC analog output, order by Model Number:

DMI-A1-111

For DMI-A1 Single-Channel Indicator for AC LVDTs, with 120-220 V AC input power, four (4) independently programmable set points, four (4) 5 A Form A relays, 0-10 V DC analog output, and RS-232 serial port, order by Model Number:

DMI-A1-811

For DMI-A1 Single-Channel Indicator for AC LVDTs, with 120-220 V AC input power, four (4) independently programmable set points, four (4) 5 A Form A relays, 0-10 V DC analog output, and Ethernet port, order by Model Number:

DMI-A1-812

For DMI-A1 Single-Channel Indicator for AC LVDTs, with 120-220 V AC input power, four (4) independently programmable set points, four (4) 5 A Form A relays, 4-20 mA output, and RS-232 serial port, order by Model Number:

DMI-A1-831

For DMI-A1 Single-Channel Indicator for AC LVDTs, with 120-220 V AC input power, four (4) independently programmable set points, four (4) 5 A Form A relays, 4-20 mA output, and Ethernet port, order by Model Number:

DMI-A1-832

For DMI-A1 Single-Channel Indicator for AC LVDTs, with 24 V DC input power, four (4) independently programmable set points, four (4) 5 A Form A relays, and
0-10 V DC analog output, order by Model Number:

DMI-A1-911

For DMI-A1 Single-Channel Indicator for AC LVDTs, with 24 V DC input power, four (4) independently programmable set points, four (4) 5 A Form A relays, 4-20 mA output, and RS-232 serial port, order by Model Number:

DMI-A1-931

Downloads
DMI-D1 Series Specifications - (click tabs above for DMC-A2 and DMI-A1 Series Specifications)
General
Digital Display 7-segment, 0.56” (14.2 mm) LEDs
Display Color Red
Display Range -19999 to 99999
Display Update Rate 10 times per second
Display Dimming 8 brightness levels. Front panel selectable
Polarity Assumed positive. Displays – negative
Annunciators 6 red LEDs on front panel
Front Panel Controls PROGRAM, UP, and DOWN buttons
Power Supplies Standard high voltage AC power supply 85-265 VAC, or optional low voltage DC power supply 10-72 V DC
Environmental
Operating Temperature 32 °F to 122 °F
0 °C to 50 °C
Storage Temperature -4 °F to 158 °F
-20 °C to 70 °C
Relative Humidity 95% (non-condensing) at 104°F (40°C)
Mechanical
Case Dimensions 1/8 DIN, 3.78” x 1.89”
96 x 48 mm
Case Depth 5.39" (137 mm) maximum
Case Material 94V-0 UL rated self-extinguishing polycarbonate
Weight 0.79 lbs., 0.96 lbs. when packed
11.5 oz., 14 oz. when packed
Approvals
CE As per EN-61000-3/4/6 and EN-61010-1
LVDT Input Module
Excitation Voltage 24 V DC
Temperature Coefficient ± 50 ppm/ °C of full scale (typ.)
LVDT Input 1M input impedance
Analog to Digital Dual scope 17 bipolar converter
Output Rate 10 Hz averaged response outputs
Line Frequency Rejection 50 or 60 Hz noise rejection
Relay Output Modules
Four Relay Module Available with four 5 A Form A Relays;
5 A 240 V AC, 4 A 24 VDC
Isolation 3000 V. UL and CSA listed
DMI-D1 Series Ordering Information

For DMI-D1 Single-Channel Indicator for DC LVDTs, with 120-220 V AC input power, four (4) independently programmable set points, four (4) 5 A Form A relays, 0-10 V DC analog output, and RS-232 serial port, order by Model Number:

DMI-D1-811

For DMI-D1 Single-Channel Indicator for DC LVDTs, with 120-220 V AC input power, four (4) independently programmable set points, four (4) 5 A Form A relays, 0-10 V DC analog output, and Ethernet port, order by Model Number:

DMI-D1-812

Downloads
Quick Contact

In less than a minute, you can contact Macro Sensors with your requirements....

* Company Name:
* Contact Name:
Questions/Comments:
* Email Address:
Phone:
Country: